Effects of thermal neutrons on MSGCs
To investigate the effects of neutrons on MSGCs, the gain of several detectors was measured before and after irradiation with a flux of 10 6 neutrons/ cm 2 s in the CEA (Saclay) ISIS reactor facility. On one of these prototypes the induced activity was measured after the irradiation.
Gespeichert in:
Veröffentlicht in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 1998-08, Vol.413 (2), p.293-296 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To investigate the effects of neutrons on MSGCs, the gain of several detectors was measured before and after irradiation with a flux of
10
6
neutrons/
cm
2
s
in the CEA (Saclay) ISIS reactor facility. On one of these prototypes the induced activity was measured after the irradiation. |
---|---|
ISSN: | 0168-9002 1872-9576 |