Oxidation induced emissivity variations of the Haynes 25 alloy at high temperatures
•Oxidation of Haynes 25 alloy was performed in air plasma flow from 1000 to 1700 K.•The mass variation versus temperature was determined up to the melting one.•A kinetic law was obtained for the oxidation carried out at 1573 K for short holding times.•Emissivity measurement was done on different sam...
Gespeichert in:
Veröffentlicht in: | Infrared physics & technology 2023-11, Vol.134, p.104930, Article 104930 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Oxidation of Haynes 25 alloy was performed in air plasma flow from 1000 to 1700 K.•The mass variation versus temperature was determined up to the melting one.•A kinetic law was obtained for the oxidation carried out at 1573 K for short holding times.•Emissivity measurement was done on different samples: pristine, pre-oxidized in air plasma and in situ oxidized in air.•The emissivity of pristine Haynes 25 is vey low, around 0.20 at 1350 K and it increases with oxidation up to 0.85–0.90 at 1600 K.
Haynes 25 alloy is used in the design of propulsion systems for spacecrafts and it can constitute a space debris at the end of life of the mission. All the thruster combustion chambers and nozzles are manufactured with Haynes 25 alloy and the thrusters used storable monopropellant hydrazine. During the atmospheric reentry of thruster pieces at high velocity, the Haynes 25 alloy is submitted to high temperatures in an extreme environment with atomic oxygen. This is why the high temperature oxidation of Haynes 25 was studied, in air plasma conditions in the temperature range 1000–1700 K. Moreover, as emissivity is an important parameter to know for the heat transfer, the spectral directional emissivity was measured on several samples surfaces: pristine, pre-oxidized in air plasma and in situ oxidized in air. The high temperature oxidation of Haynes 25 is moderate up to 1500 K and above an important mass loss occurred up to 1700 K (around 40 mg/cm2), that is the determined melting temperature. The emissivity of pristine Haynes 25 is vey low, around 0.20 at 1350 K and it increases with oxidation up to 0.85–0.90 at 1600 K. |
---|---|
ISSN: | 1350-4495 1879-0275 |
DOI: | 10.1016/j.infrared.2023.104930 |