The error structure of impedance spectra for systems with a large ohmic resistance with respect to the polarization impedance

Electrochemical impedance spectra were obtained for polyaniline membranes in weak and strong acid electrolytes. The measurement model approach for error analysis was used to show that the standard deviation of the real and imaginary parts of the impedance were equal, even for systems containing a la...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Electrochemical Society 1996-12, Vol.143 (12), p.3880-3890
Hauptverfasser: ORAZEM, M. E, MOUSTAFID, T. E, DESLOUIS, C, TRIBOLLET, B
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Electrochemical impedance spectra were obtained for polyaniline membranes in weak and strong acid electrolytes. The measurement model approach for error analysis was used to show that the standard deviation of the real and imaginary parts of the impedance were equal, even for systems containing a large solution resistance with respect to the polarization impedance. These results were confirmed using analogue RC circuits that did not require use of the measurement model approach. A model for the error structure is proposed that is in agreement with data obtained for large and small values of the solution resistance.
ISSN:0013-4651
1945-7111
DOI:10.1149/1.1837311