Practical approach to method verification in plasma and validation in cerebrospinal fluid under accreditation using a flexible scope in molecular virology: setting up the HIV, HBV and HCV Aptima™ Quant Dx assays

Background Our laboratory obtained the ISO 15189 accreditation for the plasmatic HIV-1, HBV and HCV viral load (VL) using the m2000 RealTime™ system, which was recently changed for the platform Panther®. Here, we discuss a strategy for performing method validation/verification very quickly. Methods...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical chemistry and laboratory medicine 2020-01, Vol.58 (2), p.251-260
Hauptverfasser: Lefeuvre, Caroline, Pivert, Adeline, Tran, Cong T., Lunel-Fabiani, Françoise, Ducancelle, Alexandra, Le Guillou-Guillemette, Hélène
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Our laboratory obtained the ISO 15189 accreditation for the plasmatic HIV-1, HBV and HCV viral load (VL) using the m2000 RealTime™ system, which was recently changed for the platform Panther®. Here, we discuss a strategy for performing method validation/verification very quickly. Methods We performed the mandatory (repeatability, internal quality assessment [IQA], measurement uncertainty [MU]) and optional technical verifications for CE/IVD assays using the flexible scope range A. We also performed the mandatory assays for the validation of HIV-1 VL in the cerebrospinal fluid (CSF) using the flexible scope range B. The change was checked by following up on the turnaround time (TAT). Results The coefficient of variation (CV%) for repeatability and IQA complied with the limit of 0.25 log. The MU results ranged from 0.04 to 0.25 log copies or IU/mL. The comparisons of methods showed excellent correlations (R2 = 0.96 for the three parameters) but a delayed centrifugation on HCV VL showed variations of up to 2 log IU/mL. An excellent linearity for HIV-1 in the CSF was obtained from 1.5 to 5 log copies/mL with R2 = 0.99. The TAT increased (84%-98%) in routine usage. Conclusions The three Aptima assays are well suited for routine laboratory use and can be integrated within less than 2 weeks in accordance with flexible scope range A. Our data allows us to confidently perform HIV-1 VL in CSF following flexible scope range B. Finally, we provide an organizational guide for flexible scope management in molecular virology within a short time frame.
ISSN:1434-6621
1437-4331
DOI:10.1515/cclm-2019-0502