Comparative analysis of SINC-shaped and SLR pulses performance for contiguous multi-slice fast spin-echo imaging using metamaterial-based MRI
Objective To comparatively assess the performance of highly selective pulses computed with the SLR algorithm in fast-spin echo (FSE) within the current radiofrequency safety limits using a metamaterial-based coil for wrist magnetic resonance imaging. Methods Apodized SINC pulses commonly used for cl...
Gespeichert in:
Veröffentlicht in: | Magma (New York, N.Y.) N.Y.), 2021-12, Vol.34 (6), p.929-938 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective
To comparatively assess the performance of highly selective pulses computed with the SLR algorithm in fast-spin echo (FSE) within the current radiofrequency safety limits using a metamaterial-based coil for wrist magnetic resonance imaging.
Methods
Apodized SINC pulses commonly used for clinical FSE sequences were considered as a reference. Selective SLR pulses with a time-bandwidth product of four were constructed in the MATPULSE program. Slice selection profiles in conventional T1-weighted and PD-weighted FSE wrist imaging pulse sequences were modeled using a Bloch equations simulator. Signal evolution was assessed in three samples with relaxation times equivalent to those in musculoskeletal tissues at 1.5T. Regular and SLR-based FSE pulse sequences were tested in a phantom experiment in a multi-slice mode with different gaps between slices and the direct saturation effect was investigated.
Results
As compared to the regular FSEs with a conventional transmit coil, combining the utilization of the metadevice with SLR-based FSEs provided a 23 times lower energy deposition in a duty cycle. When the slice gap was decreased from 100 to 0%, the “slice cross-talk” effect reduced the signal intensity by 15.9–17.6% in the SLR-based and by 22.9–32.3% in the regular T1-weighted FSE; and by 0.0–6.4% in the SLR-based and by 0.3–9.3% in the regular PD-weighted FSE.
Discussion and conclusion
SLR-based FSE together with the metadevice allowed to increase the slice selectivity while still being within the safe SAR limits. The “slice cross-talk” effects were conditioned by the number of echoes in the echo train, the repetition time, and T1 relaxation times. The approach was more beneficial for T1-weighted SLR-based FSE as compared to PD-weighted. The combination of the metadevice and SLR-based FSE offers a promising alternative for MR investigations that require scanning in a “Low-SAR” regime such as those for children, pregnant women, and patients with implanted devices. |
---|---|