Quantification of curium isotopes in environmental samples: drawbacks, speciation and specific tracer

In this study, drawbacks of the use of 243 Am as a tracer in order to quantify curium isotopes during a complex chemical procedure were highlighted. These drawbacks were investigated through a speciation computation simulation based on the compilation of over 50 stability constants. A new curium sta...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of radioanalytical and nuclear chemistry 2021-08, Vol.329 (2), p.545-554
Hauptverfasser: Habibi, Azza, Le Corre, Roselyne, Wampach Aubert, Christèle, Fleury, Sandrine, Hennequet, Patricia, Augeray, Céline, Galliez, Kévin, Agarande, Michelle
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, drawbacks of the use of 243 Am as a tracer in order to quantify curium isotopes during a complex chemical procedure were highlighted. These drawbacks were investigated through a speciation computation simulation based on the compilation of over 50 stability constants. A new curium standard was then characterized and used to quantify a wide 244 Cm activities range in environmental samples. Obtained results were in excellent agreement with spiked activities and more consistent than those obtained when using 243 Am as tracer.
ISSN:0236-5731
1588-2780
DOI:10.1007/s10967-021-07751-7