Rapid FTIR sensing of volcanic gases released by Strombolian explosions at Yasur volcano, Vanuatu
We report here the results of a field campaign in which a portable Fourier transform infrared (FTIR) spectrometer was used to measure gas emissions from Yasur volcano, Vanuatu, in January 2005. By collecting FTIR spectra at a high rate (about 1 Hz), we were able to observe a marked difference in the...
Gespeichert in:
Veröffentlicht in: | Applied physics. B, Lasers and optics Lasers and optics, 2006-11, Vol.85 (2-3), p.453-460 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report here the results of a field campaign in which a portable Fourier transform infrared (FTIR) spectrometer was used to measure gas emissions from Yasur volcano, Vanuatu, in January 2005. By collecting FTIR spectra at a high rate (about 1 Hz), we were able to observe a marked difference in the proportions of SO2 and HCl in emissions released during Strombolian eruptions (SO2/HCl molar ratio up to ~30 or more) compared with the intervening passive emissions discharged from the magmatic vent (SO2/HCl ~2). This contrast can be explained by sourcing gas at different depths with respect to levels at which SO2 and HCl exsolve from the melt: deeper volatile exsolution supplies relatively SO2-rich gas responsible for the ephemeral explosions at the top of the conduit; while degassing of shallow magma, depleted in sulfur but rich in chlorine, contributes to the passive emission. |
---|---|
ISSN: | 0946-2171 1432-0649 |
DOI: | 10.1007/s00340-006-2353-4 |