Determination of luminosity for in-ring reactions: A new approach for the low-energy domain

Luminosity is a measure of the colliding frequency between beam and target and it is a crucial parameter for the measurement of absolute values, such as reaction cross sections. In this paper, we make use of experimental data from the ESR storage ring to demonstrate that the luminosity can be precis...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2020-12, Vol.982, p.164367, Article 164367
Hauptverfasser: Xing, Y.M., Glorius, J., Varga, L., Bott, L., Brandau, C., Brückner, B., Chen, R.J., Chen, X., Dababneh, S., Davinson, T., Erbacher, P., Fiebiger, S., Gaßner, T., Göbel, K., Groothuis, M., Gumberidze, A., Gyürky, G., Heil, M., Hess, R., Hensch, R., Hillmann, P., Hillenbrand, P.-M., Hinrichs, O., Jurado, B., Kausch, T., Khodaparast, A., Kisselbach, T., Klapper, N., Kozhuharov, C., Kurtulgil, D., Lane, G., Langer, C., Lederer-Woods, C., Lestinsky, M., Litvinov, S., Litvinov, Yu.A., Löher, B., Petridis, N., Popp, U., Reed, M., Reifarth, R., Sanjari, M.S., Simon, H., Slavkovská, Z., Spillmann, U., Steck, M., Stöhlker, T., Stumm, J., Szücs, T., Nguyen, T.T., Zadeh, A. Taremi, Thomas, B., Torilov, S.Yu, Törnqvist, H., Trageser, C., Trotsenko, S., Volknandt, M., Wang, M., Weigand, M., Wolf, C., Woods, P.J., Zhang, Y.H., Zhou, X.H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Luminosity is a measure of the colliding frequency between beam and target and it is a crucial parameter for the measurement of absolute values, such as reaction cross sections. In this paper, we make use of experimental data from the ESR storage ring to demonstrate that the luminosity can be precisely determined by modelling the measured Rutherford scattering distribution. The obtained results are in good agreement with an independent measurement based on the x-ray normalization method. Our new method provides an alternative way to precisely measure the luminosity in low-energy stored-beam configurations. This can be of great value in particular in dedicated low-energy storage rings where established methods are difficult or impossible to apply.
ISSN:0168-9002
1872-9576
DOI:10.1016/j.nima.2020.164367