Improvement of PDP discharge efficiency based on macro-cell studies

— In this paper we explain how macro‐cells (real PDP cells scaled‐up a hundred times) with external and removable electrodes have been validated by comparison with real panels and modeling and used to optimize the luminous efficacy of real PDPs. We illustrate the application of the macroscopic PDP t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Society for Information Display 2003-09, Vol.11 (3), p.551-558
Hauptverfasser: Tessier, Laurent, Lacoste, Ana, Doyeux, Henri, Salavin, Serge, Ouyang, Jiting, Callegari, Thierry, Lebarq, Nicolas, Caillier, Bruno, Boeuf, Jean-Pierre
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:— In this paper we explain how macro‐cells (real PDP cells scaled‐up a hundred times) with external and removable electrodes have been validated by comparison with real panels and modeling and used to optimize the luminous efficacy of real PDPs. We illustrate the application of the macroscopic PDP tool to optimize the electrode configuration of short‐gap discharges towards higher luminous efficacy, as well as its use in conjunction with 2D and 3D modeling to lower the operating voltages of high‐efficacy long‐gap discharges triggered by auxiliary electrodes.
ISSN:1071-0922
1938-3657
DOI:10.1889/1.1825685