Effect of microstructural elongation on backscattered field: Intensity measurement and multiple scattering estimation with a linear transducer array

•The field backscattered by an elongated medium is integrated on rectangular transducers.•Macrograins orientation in Ti-alloys is detected by rotating a linear transducer array.•The first method exploits the angular dependence of the backscattered intensity.•The second method uses the angular depend...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ultrasonics 2018-01, Vol.82, p.379-389
Hauptverfasser: Baelde, Aurélien, Laurent, Jérôme, Millien, Pierre, Coulette, Richard, Khalifa, Warida Ben, Jenson, Frédéric, Sun, Fan, Fink, Mathias, Prada, Claire
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•The field backscattered by an elongated medium is integrated on rectangular transducers.•Macrograins orientation in Ti-alloys is detected by rotating a linear transducer array.•The first method exploits the angular dependence of the backscattered intensity.•The second method uses the angular dependence of the multiple scattering level. The effect of microstructural elongation on ultrasonic backscattered fields was studied. Two methods for determining the elongation direction of macrozones in titanium alloys, using the anisotropic spatial coherence of the backscattered field, are presented. Both methods use a phased array attached on a rotative holder that records the array response matrix at several angles. Two titanium alloys were investigated: TA6V and Ti17. TA6V exhibited a strong macrozone elongation, whereas Ti17 macrozones were found equiaxial. The first method is based on the measurement of backscattered intensity in function of the probe angle relative to the macrozones elongation direction. An angular dependence of backscattered intensity is observed in presence of elongated scatterers, and their elongation direction is collinear with the probe direction corresponding to a minimal intensity. This variability is linked to both piezoelectric shape and the backscattered field spatial properties. The second method is based on the measurement of the relative proportion of single to multiple scattering in a diffusive media, using a simplified version of the single scattering filter developed in Aubry and Derode (2009). It allows the measurement of the level of multiple scattering: both titanium alloys exhibited strong multiple scattering. The elongation direction was determined as the direction of minimal multiple scattering. Furthermore, these results were confirmed by the measurement of the coherent backscattering cone on both samples.
ISSN:0041-624X
1874-9968
DOI:10.1016/j.ultras.2017.09.006