Dissolved oxygen level output feedback control based on discrete-time measurements during a Pseudomonas putida mt-2 fermentation

•Original high-gain control of pO2.•Continuous-discrete estimators of pO2 and rO2.•Stability proof of the underlying output feedback control law.•Successful experimental results. In this paper, the problem of controlling the dissolved oxygen level (DO) during an aerobic fermentation is considered. T...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of process control 2019-07, Vol.79, p.29-40
Hauptverfasser: Gehan, O., Pigeon, E., Menard, T., Mosrati, R., Pouliquen, M., Fall, L.M., Reuter, J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Original high-gain control of pO2.•Continuous-discrete estimators of pO2 and rO2.•Stability proof of the underlying output feedback control law.•Successful experimental results. In this paper, the problem of controlling the dissolved oxygen level (DO) during an aerobic fermentation is considered. The proposed approach deals with three major difficulties in respect to the nonlinear dynamics of the DO, the poor accuracy of the empirical models for the oxygen consumption rate and the fact that only sampled measurements are available on-line. A nonlinear integral high-gain control law including a continuous-discrete time observer is designed to keep the DO in the neighborhood of a set point value without any knowledge on the dissolved oxygen consumption rate. The local stability of the control algorithm is proved using Lyapunov tools. The performance of the control scheme is first analyzed in simulation and then experimentally evaluated during a successfull fermentation of the bacteria over a period of three days. Pseudomonas putida mt-2.
ISSN:0959-1524
1873-2771
DOI:10.1016/j.jprocont.2018.10.004