Electrochromic biosensors based on screen-printed Prussian Blue electrodes

•We present the production of an electrochromic screen-printable paste based on Prussian Blue.•These electrodes display high reversibility and electrocatalysis toward H2O2 reduction.•These blue electrodes enable both the electrochemical and optical quantitative determination of hydrogen peroxide.•Th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 2019-07, Vol.290, p.591-597
Hauptverfasser: Aller-Pellitero, Miguel, Fremeau, Joséphine, Villa, Rosa, Guirado, Gonzalo, Lakard, Boris, Hihn, Jean-Yves, del Campo, F. Javier
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•We present the production of an electrochromic screen-printable paste based on Prussian Blue.•These electrodes display high reversibility and electrocatalysis toward H2O2 reduction.•These blue electrodes enable both the electrochemical and optical quantitative determination of hydrogen peroxide.•The reported blue electrodes are highly suitable transducers for the construction of oxidase-based biosensors.•A glucose biosensor is presented to demonstrate the spectroelectrochemical capabilities of these new electrodes. Prussian Blue (PB)-modified graphite screen-printed electrodes are increasingly being used in electrochemical biosensors. However, they do not allow the observation of the electrochromism of PB. This work presents the construction of PB-based, electrochromic screen-printed biosensors. Although electrically more resistive than their graphite counterparts, these new PB-based electrodes enable both the amperometric and colorimetric detection of hydrogen peroxide. This is the first time that this has been achieved using screen-printed electrodes, and we demonstrate it spectroelectrochemically on a glucose biosensor. The biosensor electrochemical performance equals that of previously reported PB/graphite electrodes, being able to detect down to 4 μM H2O2 and 54 μM glucose. At the same time, and in contrast to PB/graphite electrodes, the new PB-based electrodes afford the optical detection of these two analytes down to 1.2 μM and 15 μM, respectively. The dynamic ranges of the glucose biosensors obtained at the PB-based electrodes are 0.1–1 mM (amperometric) and 0.025–2.5 mM (Colorimetric), matching the physiological glucose concentration range in body fluids other than blood or serum.
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2019.03.100