Crack initiation and propagation under thermal fatigue of austenitic stainless steel

•Thermal fatigue tests are performed with pulsed laser on AISI 316L(N) samples.•Hybrid Multiview Correlation (HMC) is used to measure thermomechanical fields.•Crack initiation and propagation stages are tracked in-situ via HMC measurements.•Crack networks span over the thermally shocked surface and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of fatigue 2019-07, Vol.124, p.149-166
Hauptverfasser: Wang, Yanjun, Charbal, Ali, Hild, François, Roux, Stéphane, Vincent, Ludovic
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Thermal fatigue tests are performed with pulsed laser on AISI 316L(N) samples.•Hybrid Multiview Correlation (HMC) is used to measure thermomechanical fields.•Crack initiation and propagation stages are tracked in-situ via HMC measurements.•Crack networks span over the thermally shocked surface and penetrate less in-depth.•Conservative results are obtained compared with isothermal uniaxial fatigue tests. Thermal fatigue tests on AISI 316L(N) austenitic stainless steel samples are performed through pulsed laser on specimen that can be subjected to an additional static mechanical load. These tests are carried out in Helium environment with a dedicated and heavily instrumented set-up. The fatigued surface is monitored by a hybrid multiview system composed of two visible light and one infrared cameras that, through 3D-registration, provides in-situ access to the 3D surface displacement fields and 2D temperature fields. At a fatigue frequency of 1 Hz, the surface temperature range covered per cycle can be varied from 150 °C to 250 °C, conditions that allow surface damage to be reproduced. The multiview system reveals the time-resolved mechanisms of surface damage, from significant cyclic plasticity with persistent slip bands to microcrack initiation and growth, leading to their quantitative characterization (microcrack density, length of major crack, orientation) all along the test. These observations are confirmed at a few check points where the test is interrupted for optical microscopy inspection of the surface. Finally, the thermal fatigue data are compared to purely mechanical isothermal uniaxial fatigue data through the use of an equivalent strain, and an excellent (and conservative) agreement is obtained.
ISSN:0142-1123
1879-3452