Hydrogen solubility in straight run gasoil

The solubility of hydrogen in a straight run gasoil is measured using a chromatographic method, which is first validated with a known organic liquid (cyclohexane). Under the experimental conditions (up to 4 MPa , temperatures from 298 to 675 K ), these results are best described by Chao–Seader and i...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Chemical engineering science 2002-02, Vol.57 (4), p.547-553
Hauptverfasser: Ronze, Didier, Fongarland, Pascal, Pitault, Isabelle, Forissier, Michel
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The solubility of hydrogen in a straight run gasoil is measured using a chromatographic method, which is first validated with a known organic liquid (cyclohexane). Under the experimental conditions (up to 4 MPa , temperatures from 298 to 675 K ), these results are best described by Chao–Seader and improved Zudkevitch–Joffe (with adjustment parameter b 0=0.6) models. Henry's law constant is determined at four temperatures.
ISSN:0009-2509
1873-4405
DOI:10.1016/S0009-2509(01)00404-3