Radiation dosimetry of [131I]ICF01012 in rabbits: Application to targeted radionuclide therapy for human melanoma treatment

Purpose Dosimetry for melanoma‐targeted radionuclide therapy (TRT) with [131I]ICF01012, a melanin ligand, has been previously evaluated in mice bearing melanomas. In this study, activity distribution and dosimetry are performed on healthy rabbits (Fauve de Bourgogne) using SPECT‐CT imaging and ex vi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical physics (Lancaster) 2018-11, Vol.45 (11), p.5251-5262
Hauptverfasser: Jouberton, Elodie, Perrot, Yann, Dirat, Béatrice, Billoux, Tommy, Auzeloux, Philippe, Cachin, Florent, Chezal, Jean‐Michel, Filaire, Marc, Labarre, Pierre, Miot‐Noirault, Elisabeth, Millardet, Corinne, Valla, Clémence, Vidal, Aurélien, Degoul, Françoise, Maigne, Lydia
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose Dosimetry for melanoma‐targeted radionuclide therapy (TRT) with [131I]ICF01012, a melanin ligand, has been previously evaluated in mice bearing melanomas. In this study, activity distribution and dosimetry are performed on healthy rabbits (Fauve de Bourgogne) using SPECT‐CT imaging and ex vivo measurements. Material and Methods Ex vivo biodistribution (i.v. injection: 370 kBq/kg, n = 2 per point) is performed on blood, eyes, brain, lung, liver, kidneys, heart, stomach, and spleen. Dosimetry calculations follow the MIRD formalism: S values are calculated from CT images using the GATE Monte Carlo platform and activity distributions are obtained from SPECT‐CT imaging (i.v. injection: 37 MBq/kg n = 3 per point). A specific study is presented to assess dose to human retina. Results Time‐integrated activities based on SPECT‐CT are in accordance with ex vivo measurements except for spleen. Doses to liver and eyes are the most significant, with respectively, 6.38 ± 0.50 Gy/GBq (evaluated through SPECT‐CT imaging) and 45.8 ± 7.9 Gy/GBq (evaluated through ex vivo measurements). Characterization of ocular [131I]ICF01012 biodistribution in rabbits and quantification of melanin allowed to assess a dose of 3.07 ± 0.70 Gy/GBq to human retina. Conclusion This study sustains [131I]ICF01012 as a good candidate for melanoma TRT and open perspectives for personalized dosimetry calculation during phase I clinical transfer.
ISSN:0094-2405
2473-4209
DOI:10.1002/mp.13165