Predictors and Clinical Impact of Late Ventricular Arrhythmias in Patients With Continuous-Flow Left Ventricular Assist Devices

This study aimed to evaluate the incidence, clinical impact, and predictors of late ventricular arrhythmias (VAs) in left ventricular assist device (LVAD) recipients aiming to clarify implantable cardioverter-defibrillator (ICD) indications. The arrhythmic risk and need for ICD in patients implanted...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JACC. Clinical electrophysiology 2018-09, Vol.4 (9), p.1166-1175
Hauptverfasser: Galand, Vincent, Flécher, Erwan, Auffret, Vincent, Boulé, Stéphane, Vincentelli, André, Dambrin, Camille, Mondoly, Pierre, Sacher, Frédéric, Nubret, Karine, Kindo, Michel, Cardi, Thomas, Gaudard, Philippe, Rouvière, Philippe, Michel, Magali, Gourraud, Jean-Baptiste, Defaye, Pascal, Chavanon, Olivier, Verdonk, Constance, Ghodbane, Walid, Pelcé, Edeline, Gariboldi, Vlad, Pozzi, Matteo, Obadia, Jean-François, Litzler, Pierre-Yves, Anselme, Frédéric, Babatasi, Gerard, Belin, Annette, Garnier, Fabien, Bielefeld, Marie, Hamon, David, Radu, Costin, Pierre, Bertrand, Bourguignon, Thierry, Eschalier, Romain, D’Ostrevy, Nicolas, Bories, Marie-Cécile, Marijon, Eloi, Vanhuyse, Fabrice, Blangy, Hugues, Verhoye, Jean-Philippe, Leclercq, Christophe, Martins, Raphaël P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study aimed to evaluate the incidence, clinical impact, and predictors of late ventricular arrhythmias (VAs) in left ventricular assist device (LVAD) recipients aiming to clarify implantable cardioverter-defibrillator (ICD) indications. The arrhythmic risk and need for ICD in patients implanted with an LVAD are not very well known. This observational study was conducted in 19 centers between 2006 and 2016. Late VAs were defined as sustained ventricular tachycardia or fibrillation occurring >30 days post-LVAD implantation, without acute reversible cause and requiring appropriate ICD therapy, external electrical shock, or medical therapy. Among 659 LVAD recipients, 494 (median 58.9 years of age; mean left ventricular ejection fraction 20.7 ± 7.4%; 73.1% HeartMate II, 18.6% HeartWare, 8.3% Jarvik 2000) were discharged alive from hospital and included in the final analysis. Late VAs occurred in 133 (26.9%) patients. Multivariable analysis identified 6 independent predictors of late VAs: VAs before LVAD implantation, atrial fibrillation before LVAD implantation, idiopathic etiology of the cardiomyopathy, heart failure duration >12 months, early VAs (
ISSN:2405-500X
2405-5018
DOI:10.1016/j.jacep.2018.05.006