Methodology for airflow rate measurements in a naturally ventilated mock-up animal building with side and ridge vents

Currently there exists no generally accepted reference technique to measure the ventilation rate through naturally ventilated (NV) vents. This has an impact on the reliability of airflow rate control techniques and emission rate measurements in NV animal houses. As an attempt to address this issue a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Building and environment 2016-08, Vol.105, p.153-163
Hauptverfasser: Van Overbeke, P., De Vogeleer, G., Mendes, L.B., Brusselman, E., Demeyer, P., Pieters, J.G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Currently there exists no generally accepted reference technique to measure the ventilation rate through naturally ventilated (NV) vents. This has an impact on the reliability of airflow rate control techniques and emission rate measurements in NV animal houses. As an attempt to address this issue a NV test facility was built to develop new airflow rate measurement techniques for both side wall and ridge vents. Three set-ups were used that differed in vent configuration, i.e. one cross ventilated set-up and two ridge ventilated set-ups with different vent sizes. The airflow through the side vents was measured with a technique based on an automatic traverse movement of a 3D ultrasonic anemometer. In the ridge, 7 static 2D ultrasonic anemometers were installed. The methods were validated by applying the air mass conservation principle, i.e. the inflow rates must equal the outflow rates. The calculated in - and outflow rates agreed within (5 ± 8)%, (8 ± 5)% and (−9 ± 7)% for the three different set-ups respectively, over a large range of wind incidence angles. It was found that the side vent configuration was of large importance for the distribution of the airflow rates through the vents. The ridge proved to be a constant outlet, whilst side vents could change from outlet to inlet depending on the wind incidence angle. The range of wind incidence angles in which this transition occurred could be clearly visualized. •A naturally cross and ridge ventilated test facility was built.•An airflow rate measuring method for side vents and ridge was developed.•The method was successfully validated through the law of mass conservation.•Experiments were conducted under a large range of wind incidence angles and speeds.
ISSN:0360-1323
1873-684X
DOI:10.1016/j.buildenv.2016.05.036