Membrane contactors for intensified post combustion carbon dioxide capture by gas–liquid absorption in MEA: A parametric study
► The intensification factor of a membrane contactor vs. a packed column is quantitatively investigated for CO2 capture. ► Conditions (membrane material, module, operating parameters) which maximize the intensification of a membrane contactor for CO2 capture are identified. ► A minimal membrane perm...
Gespeichert in:
Veröffentlicht in: | Chemical engineering research & design 2012-12, Vol.90 (12), p.2325-2337 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | ► The intensification factor of a membrane contactor vs. a packed column is quantitatively investigated for CO2 capture. ► Conditions (membrane material, module, operating parameters) which maximize the intensification of a membrane contactor for CO2 capture are identified. ► A minimal membrane permeance of 2×10−3ms−1 is needed in order to achieve intensification. ► Overall contactor volume can be divided by a factor of about 11 compared to the volume of an absorption column. ► Pressure drop effects are taken into account for membrane contactor simulation in CO2 capture.
Post combustion carbon dioxide capture raises tremendous chemical engineering challenges. For the first generation of industrial installations, gas liquid absorption in chemical solvents is classically considered to be the best available technology. Two major bottlenecks have however to be solved in order to achieve technico-economical targets: decrease the energy requirement of the process (e.g. through novel solvents or heat integration approaches) and decrease the size of the installation (through process intensification).
This study intends to explore the possibilities and limitations of membrane contactors, which are considered as one of the most promising strategy for intensified CO2 capture by gas–liquid absorption. A very large number of studies is continuously reported on this topic, including materials, mass transfer or process design issues, but a rigorous evaluation of their effective potential in terms of intensification is still lacking. Moreover, controversial results have been reported such as intensification factors, compared to packed columns, ranging between 10 and 0.8 on a total unit volume basis.
This unclear situation results from different factors. First, experimental comparison of membrane contactors vs. packed absorption columns performances is indeed seldom. Second, the evaluation of membrane contactors is systematically performed at laboratory scale, under operating conditions which do not necessarily reflect industrial operation (i.e. fresh amine solutions are used, limited capture ratio are achieved). These simplifying assumptions have obviously to be reconsidered if a realistic comparison for industrial operation is aimed. More importantly, pressure drop levels, which are known to be very small for packed columns (typically 50mBar on the gas side for an industrial packed column), have to be considered in order to minimize the energy impact of the process. An a |
---|---|
ISSN: | 0263-8762 1744-3563 |