Accuracy of ground surface broadband shortwave radiation monitoring

The uncertainty of broadband shortwave radiation monitoring is determined for direct, diffuse, and global irradiance for measurements obtained at the Payerne (Switzerland) station of the Baseline Surface Radiation Network (BSRN). The uncertainty estimates include sources that reflect realistic long‐...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of geophysical research. Atmospheres 2014-12, Vol.119 (24), p.13,838-13,860
Hauptverfasser: Vuilleumier, L., Hauser, M., Félix, C., Vignola, F., Blanc, P., Kazantzidis, A., Calpini, B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The uncertainty of broadband shortwave radiation monitoring is determined for direct, diffuse, and global irradiance for measurements obtained at the Payerne (Switzerland) station of the Baseline Surface Radiation Network (BSRN). The uncertainty estimates include sources that reflect realistic long‐term operation conditions. The uncertainties are derived using the methodology specified by the “Guide to the expression of uncertainty in measurement.” The differences between redundant determinations of direct, diffuse, and global irradiance are analyzed and are shown to be compatible with the uncertainties. In addition, the signatures of some uncertainty sources are sought within the error statistics to find out if corrections can be applied and what their magnitude is. The global and diffuse irradiance uncertainties range from 1.8% to 2.4% without correction and are less than 1.8% with corrections. These uncertainties are close to or satisfy the BSRN targets for large signals (global: 1000 W m−2, diffuse: 500 W m−2). For small signals (50 W m−2), the targets are not achieved, mainly as a result of uncertainties associated with the data acquisition electronics (DAQ). The direct irradiance uncertainty is ~1.5%, 3 times larger than the BSRN uncertainty target. An accuracy gain can also be achieved at the DAQ level, but even without considering the DAQ uncertainty, the target is exceeded by a factor of about 2. The direct irradiance uncertainty remains ~1% even using an absolute cavity radiometer as transfer standard for correcting the pyrheliometer sensitivity. Thus, the direct irradiance accuracy target of 0.5% is probably not achievable with the best commercially available technology. Key Points The uncertainty of ground surface shortwave radiation monitoring is determinedRealistic operating conditions using best available technology are consideredThe most stringent BSRN accuracy target may not be currently achievable
ISSN:2169-897X
2169-8996
DOI:10.1002/2014JD022335