Vectorial Approach-Based Control of a Seven-Phase Axial Flux Machine Designed for Fault Operation

This paper deals with easy-to-implement control strategies when a seven-phase axial flux permanent magnet machine supplied by a seven-leg voltage source inverter is in fault operation mode. Using a vectorial multimachine description, a seven-phase machine presenting a heightened ability to be contro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industrial electronics (1982) 2008-10, Vol.55 (10), p.3682-3691
Hauptverfasser: Locment, F., Semail, E., Kestelyn, X.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper deals with easy-to-implement control strategies when a seven-phase axial flux permanent magnet machine supplied by a seven-leg voltage source inverter is in fault operation mode. Using a vectorial multimachine description, a seven-phase machine presenting a heightened ability to be controlled with one or two open-circuited phases has been designed. The machine is first presented, and experimental results are provided when one or two phases are open circuited. Based on a vectorial approach, new current references are calculated to avoid high-torque ripples.
ISSN:0278-0046
1557-9948
DOI:10.1109/TIE.2008.925313