Sky temperature modelisation and applications in building simulation

The sky temperature is an important parameter for simulation codes in building studies. A preliminary campaign of validation of a simulation software CODYRUN has demonstrated the misinterpretation of the radiative exchanges of long waves between the building and its environment. A bibliographical re...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Renewable energy 1998-09, Vol.15 (1), p.418-430
Hauptverfasser: Adelard, L., Pignolet-Tardan, F., Mara, T., Lauret, P., Garde, F., Boyer, H.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The sky temperature is an important parameter for simulation codes in building studies. A preliminary campaign of validation of a simulation software CODYRUN has demonstrated the misinterpretation of the radiative exchanges of long waves between the building and its environment. A bibliographical research has then led to the use models using dry air temperature to estimate sky temperature. However, these models has not been completely satisfactory as far as night clear sky are concerned. In this case, sky temperature remains overestimated. A research of a non linear model has been undertaken, leading to the use of neural networks with satisfactory results. Sky temperature is then calculated and reinjected into the simulation code. Comparison between simulated temperature and measures has turned to be acceptable.
ISSN:0960-1481
1879-0682
DOI:10.1016/S0960-1481(98)00198-0