Quantitative Determination of Gymnodimine-A by High Performance Liquid Chromatography in Contaminated Clams from Tunisia Coastline

Quantitative determination by high performance liquid chromatography (HPLC) was performed for gymnodimine-A (GYM-A), a phycotoxin responsible for the contamination of Tunisian clams. This study demonstrates a rapid and reproducible HPLC-ultraviolet (UV) method for extraction, detection and quantific...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Marine biotechnology (New York, N.Y.) N.Y.), 2010-10, Vol.12 (5), p.579-585
Hauptverfasser: Marrouchi, Riadh, Dziri, Faten, Belayouni, Nawel, Hamza, Asma, Benoit, Evelyne, Molgó, Jordi, Kharrat, Riadh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Quantitative determination by high performance liquid chromatography (HPLC) was performed for gymnodimine-A (GYM-A), a phycotoxin responsible for the contamination of Tunisian clams. This study demonstrates a rapid and reproducible HPLC-ultraviolet (UV) method for extraction, detection and quantification of GYM-A in toxic clams. The extraction of GYM-A from the digestive gland of clams in acetone, subsequent clean-up with diethyl ether and extraction with dichloromethane is the more valid protocol. Chromatography analyses were performed using a gradient of acetonitrile-water (10:90 to 90:10), containing trifluoroacetic acid (0.1%) for 20 min at 1 mL/min rate with a C18 column. Recovery rates exceeded 96%, and limits of detection and quantification were 5 ng/mL and 8 ng/g digestive gland, respectively. Repeatability and reproducibility were tested for various samples containing different levels of GYM-A. A significant correlation was observed between toxicity level of samples and the determined amount of GYM-A. Also, the persistence of GYM-A in contaminated clams from Boughrara lagoon was demonstrated. The kinetics discharge study of GYM-A in controlled medium, during 1 month, showed that the process of depuration was biphasic with an exponential discharge of 75% of the total amount of sequestered GYM-A during the first 12 days followed by a slow discharge (>10%) for the subsequent days up to the seventeenth day. This is the first time that a quantitative study of GYM-A in clams from Tunisian coasts is performed through the development of a new method for detection and quantify of this phycotoxin. We found HPLC-UV a reliable and suitable alternative to the mouse bioassay.
ISSN:1436-2228
1436-2236
DOI:10.1007/s10126-009-9245-7