Electret Properties of CR-39

The behaviour of CR-39 (which is a solid track detector) as an electret is compared with other classical electret materials (Teflon, Mylar). The initial charge obtained, principally by a corona method, and its decay have been studied; the result for the charge of CR-39 is similar to that for other p...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Radiation protection dosimetry 1987-01, Vol.20 (4), p.249-252
Hauptverfasser: Makovicka, L., Moliton, A., Guille, B., Teyssier, J.L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The behaviour of CR-39 (which is a solid track detector) as an electret is compared with other classical electret materials (Teflon, Mylar). The initial charge obtained, principally by a corona method, and its decay have been studied; the result for the charge of CR-39 is similar to that for other polymer electrets and the decay is intermediate between that of Teflon and Mylar. Some results of X ray and neutron irradiations are then presented. They show significant responses of CR-39 subjected to X ray beams of approximately 10-2 Gy.
ISSN:0144-8420
1742-3406
1742-3406
DOI:10.1093/oxfordjournals.rpd.a080039