An Eco-Friendly, Interference, and Solvent Free Surfactant-Assisted Dual-Wavelength β -CorrectionSpectrometric Method for Total Determination and Speciation of Cu[sup.2+] Ions in Water
Spectral interference through the presence of uninformative variables, excess reagents, and complications in the refinement of the analyte signal is common in the quest to identify complex species in real samples. Therefore, an economical green, facile, and sensitive strategy has been developed for...
Gespeichert in:
Veröffentlicht in: | International journal of analytical chemistry 2023-11, Vol.2023 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Spectral interference through the presence of uninformative variables, excess reagents, and complications in the refinement of the analyte signal is common in the quest to identify complex species in real samples. Therefore, an economical green, facile, and sensitive strategy has been developed for Cu[sup.2+] detection using the anionic surfactant sodium dodecylsulphate- (SDS-) assisted dual-wavelength β -correction spectrophotometric strategy combined with the chromogenic reagent zincon (ZI). The low limits of detection (LOD) and quantification (LOQ) of Cu[sup.2+] using ordinary (single wavelength) spectrophotometry were 0.19 (3.02) and 0.63 (10.0)μ gmL[sup.-1], and these values were improved to 0.08 (1.27) and 0.26μ gmL[sup.-1] (4.12μ M)) using β -correction (dual wavelength) spectrophotometry, respectively. The LOD and LOQ were improved from 0.08 (1.27) and 0.26 (4.12)μ gmL[sup.-1] to 0.02 (0.32) and 0.08μ gmL[sup.-1] (1.27μ M) using SDS-assisted dual-β -correction spectrometry, respectively. Ringbom, s, and the corrected absorbance (A[sub.c]) versus Cu[sup.2+] concentration plots were linear over the concentration range 1.10-2.4 (17.4-38.1) and 0.50-2.40μ gmL[sup.-1] (7.94-38.1μ M), respectively. Sandell's sensitivity index of 3.0×10[sup.-3]μ g/cm[sup.2] was achieved. The selectivity was further confirmed via monitoring the impact of common diverse ions and surfactants on the corrected absorbance. Total determination and Cu[sup.2+] speciation in water were favorably implemented and validated by ICP-OES at 95% (P=0.05). Satisfactory Cu[sup.2+] recoveries in tap (92.2-98.0%) and mineral (105-111.0%) water samples were achieved. The sensing system is simple, reliable, sensitive, and selective for Cu[sup.2+] detection. |
---|---|
ISSN: | 1687-8760 |
DOI: | 10.1155/2023/5001869 |