Enhancing the interferon-[gamma] release assay through omission of nil and mitogen values

Purpose To address the limited utility of the interferon (IFN)-[gamma] release assay (IGRA) caused by its variability and inconsistency. Methods This retrospective cohort study was based on data obtained between 2011 and 2019. QuantiFERON-TB Gold-In-Tube was used to measure IFN-[gamma] levels in nil...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Respiratory research 2023-07, Vol.24 (1)
Hauptverfasser: Jung, Yun Jung, Park, Ji Eun, Park, Ji Won, Lee, Keu Sung, Chung, Wou Young, Park, Joo Hun, Sheen, Seung Soo, You, Seulgi, Sun, Joo Sung, Park, Kyung Joo, Kim, Youn Jung, Park, Kwang Joo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose To address the limited utility of the interferon (IFN)-[gamma] release assay (IGRA) caused by its variability and inconsistency. Methods This retrospective cohort study was based on data obtained between 2011 and 2019. QuantiFERON-TB Gold-In-Tube was used to measure IFN-[gamma] levels in nil, tuberculosis (TB) antigen, and mitogen tubes. Results Of 9,378 cases, 431 had active TB. The non-TB group comprised 1,513 IGRA-positive, 7,202 IGRA-negative, and 232 IGRA-indeterminate cases. Nil-tube IFN-[gamma] levels were significantly higher in the active TB group (median = 0.18 IU/mL; interquartile range: 0.09-0.45 IU/mL) than in the IGRA-positive non-TB (0.11 IU/mL; 0.06-0.23 IU/mL) and IGRA-negative non-TB (0.09 IU/mL; 0.05-0.15 IU/mL) groups (P < 0.0001). From receiver operating characteristic analysis, TB antigen tube IFN-[gamma] levels had higher diagnostic utility for active TB than TB antigen minus nil values. In a logistic regression analysis, active TB was the main driver of higher nil values. In the active TB group, after reclassifying the results based on a TB antigen tube IFN-[gamma] level of 0.48 IU/mL, 14/36 cases with negative results and 15/19 cases with indeterminate results became positive, while 1/376 cases with positive results became negative. Overall, the sensitivity for detecting active TB improved from 87.2 to 93.7%. Conclusion The results of our comprehensive assessment can aid in IGRA interpretation. Since nil values are governed by TB infection rather than reflecting background noise, TB antigen tube IFN-[gamma] levels should be used without subtracting nil values. Despite indeterminate results, TB antigen tube IFN-[gamma] levels can be informative. Keywords: Tuberculosis, Interferon-[gamma], Immunological tests, Latent tuberculosis, Release assay
ISSN:1465-9921
DOI:10.1186/s12931-023-02485-4