An Extended Hybrid Analytical Model for the Shielding Effectiveness Prediction of a Multi-Cavity Structure with Numerous Apertures

In this paper, we extend our previously published hybrid analytical model which is for the estimation of shielding effectiveness of a dual-cavity structure with an aperture array to generalize the model for a wider range of applications. In the proposed model, the aperture array in the center, off-c...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Progress in electromagnetics research M Pier M 2020-10, Vol.96, p.181
Hauptverfasser: Shen, Wei, Wang, Sen, Li, Wei, Jin, Hai, Zhan, Hongliang
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, we extend our previously published hybrid analytical model which is for the estimation of shielding effectiveness of a dual-cavity structure with an aperture array to generalize the model for a wider range of applications. In the proposed model, the aperture array in the center, off-center, higher-order modes, and multi-cavity structure are taken into consideration, respectively. At last, a comparison of the results calculated by the extended hybrid analytical model with those obtained by the simulation software CST is given. The results show that the extended hybrid analytical model for the shielding effectiveness prediction of a three-cavity structure with numerous apertures has a higher precision and a higher efficiency.