ON POWER OF THE CONTROL CHART FOR ZERO TRUNCATED BINOMIAL DISTRIBUTION UNDER MISCLASSIFICATION ERROR

In this paper a mathematical investigation has been made on the effect of misclassification due to measurement error on power of the control chart for zero truncated binomial distribution (ZTBD):. Analytical formulas are obtained for calculating probabilities of errors of misclassification due to me...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Investigación operacional 2019-09, Vol.40 (3), p.330
Hauptverfasser: Chakraborty, Ashit B, Khurshid, Anwer
Format: Artikel
Sprache:eng ; spa
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper a mathematical investigation has been made on the effect of misclassification due to measurement error on power of the control chart for zero truncated binomial distribution (ZTBD):. Analytical formulas are obtained for calculating probabilities of errors of misclassification due to measurement error. The connection between apparent fraction defective (AFD) and true fraction defective (TFD) has been used to study the power of control chart. Expressions of average run length (ARL) and OC curve are also obtained.
ISSN:0257-4306