Timber moment connections using glued-in basalt FRP rods
•Glued-in rods as moment connections in partial portal frames was investigated.•Design was based on failure of the timber surrounding the glued-in rod connection.•Additional rods do not significantly impact the strength of the frame. Glued-in rods offer an alternative method for creating structural...
Gespeichert in:
Veröffentlicht in: | Construction & building materials 2017-08, Vol.145, p.226-235 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Glued-in rods as moment connections in partial portal frames was investigated.•Design was based on failure of the timber surrounding the glued-in rod connection.•Additional rods do not significantly impact the strength of the frame.
Glued-in rods offer an alternative method for creating structural timber connections however despite decades of research they have had limited implementation. The behaviour of glued-in rod connections in a framed structure was investigated. Nine partial frames were constructed of box sections connected with 12mm diameter BFRP rods. A theoretical design approach was developed based on the optimum observed behaviour, where failure was located in the connection. For specimens with two embedded rods the theory predicted strength within 16% error of the experimental results. For specimens with two rods but gave an over-prediction of strength where three rods were used. |
---|---|
ISSN: | 0950-0618 1879-0526 |