Permeability loss in porous asphalt due to binder creep
[Display omitted] ► Currently, porous asphalt loses its permeability due to clogging and over compaction. ► We quantify another source of permeability loss which is binder creep. ► In this study, specimens were subjected to various temperatures up to 60days. ► Higher permeability loss was resulted o...
Gespeichert in:
Veröffentlicht in: | Construction & building materials 2012-05, Vol.30 (1), p.10-15 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | [Display omitted]
► Currently, porous asphalt loses its permeability due to clogging and over compaction. ► We quantify another source of permeability loss which is binder creep. ► In this study, specimens were subjected to various temperatures up to 60days. ► Higher permeability loss was resulted on samples subjected to elevated temperatures. ► Binder creep disrupted air voids continuity and causing the permeability to reduce.
After several years in service, porous asphalt looses permeability primarily due to clogging. This paper presents a phenomenon, postulated as binder creep, as another source of permeability loss in porous asphalt. To ascertain the binder creep phenomenon, samples were separately conditioned at 15°C, 20°C, 30°C and 35°C. Permeability measurements were carried out at regular intervals up to 60days using a falling head water permeameter. Permeability reduction was quantified in terms of increased time of flow and reduced coefficient of permeability over time. The results showed that, permeability loss was more significant on samples conditioned at high temperatures. Statistical analyses showed that temperature and time have significant effect on permeability reduction of the porous mixes tested. Over an extended period of time and due to gravitational forces, it was postulated that binder creep in the mix had taken place which steadily disrupted air voids continuity and subsequently caused the mix permeability to reduce. Permeability reduction took place more rapidly during the first week but later tend to asymptote. This finding implies the need to specify a time frame within which porous asphalt permeability measurements must be made. A recommended practice would be to conduct the permeability test not exceeding 1day after the porous asphalt samples were compacted to eliminate inaccuracies in permeability measurements due to interference by binder creep. |
---|---|
ISSN: | 0950-0618 1879-0526 |
DOI: | 10.1016/j.conbuildmat.2011.11.038 |