Long-term bond performance of GFRP bars in concrete under temperature ranging from 20 °C to 80 °C
Eighty pull-out specimens were used to study the effect of temperature ranging from 20 °C to 80 °C in dry environment on bond properties between Glass Fiber Reinforced Polymer (GFRP) bars and concrete. The pullout-test specimens were subjected during 4 and 8 months to high temperatures up to 80 °C a...
Gespeichert in:
Veröffentlicht in: | Construction & building materials 2011-02, Vol.25 (2), p.486-493 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Eighty pull-out specimens were used to study the effect of temperature ranging from 20
°C to 80
°C in dry environment on bond properties between Glass Fiber Reinforced Polymer (GFRP) bars and concrete. The pullout-test specimens were subjected during 4 and 8
months to high temperatures up to 80
°C and then compared to untreated specimens (20
°C). Experimental results showed no significant reduction on bond strength for temperatures up to 60
°C. However, a maximum of 14% reduction of the bond strength was observed for 80
°C temperature after 8
months of thermal loading. For treated specimens, the coefficient
β in the CMR model, which predicts the bond–stress–displacement behavior, seems to be dependant with the temperature. |
---|---|
ISSN: | 0950-0618 1879-0526 |
DOI: | 10.1016/j.conbuildmat.2009.12.040 |