Comparison of the McGrath.sup.[R] .sup.Series 5 and GlideScope.sup.[R] .sup.Ranger with the Macintosh laryngoscope by paramedics

Background Out-of-hospital endotracheal intubation performed by paramedics using the Macintosh blade for direct laryngoscopy is associated with a high incidence of complications. The novel technique of video laryngoscopy has been shown to improve glottic view and intubation success in the operating...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Scandinavian journal of trauma, resuscitation and emergency medicine resuscitation and emergency medicine, 2011-01, Vol.19, p.4
Hauptverfasser: Piepho, Tim, Weinert, Kathrin, Heid, Florian M, Werner, Christian, Noppens, Rüdiger R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Out-of-hospital endotracheal intubation performed by paramedics using the Macintosh blade for direct laryngoscopy is associated with a high incidence of complications. The novel technique of video laryngoscopy has been shown to improve glottic view and intubation success in the operating room. The aim of this study was to compare glottic view, time of intubation and success rate of the McGrath.sup.[R] .sup.Series 5 and GlideScope.sup.[R] .sup.Ranger video laryngoscopes with the Macintosh laryngoscope by paramedics. Methods Thirty paramedics performed six intubations in a randomised order with all three laryngoscopes in an airway simulator with a normal airway. Subsequently, every participant performed one intubation attempt with each device in the same manikin with simulated cervical spine rigidity using a cervical collar. Glottic view, time until visualisation of the glottis and time until first ventilation were evaluated. Results Time until first ventilation was equivalent after three intubations in the first scenario. In the scenario with decreased cervical motion, the time until first ventilation was longer using the McGrath.sup.[R] .sup.compared to the GlideScope.sup.[R] .sup.and AMacintosh (p [less than] 0.01). The success rate for endotracheal intubation was similar for all three devices. Glottic view was only improved using the McGrath.sup.[R] .sup.device (p [less than] 0.001) compared to using the Macintosh blade. Conclusions The learning curve for video laryngoscopy in paramedics was steep in this study. However, these data do not support prehospital use of the McGrath.sup.[R] .sup.and GlideScope.sup.[R] .sup.devices by paramedics.
ISSN:1757-7241
1757-7241
DOI:10.1186/1757-7241-19-4