A modified on-site water chamber tester for masonry walls

The paper begins with a review of the currently available on-site water-tightness tests for masonry walls. The development of a modified on-site water chamber tester is reported. Results derived from experiments using this new tester are discussed. The results show that the leakage rate is not signi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Construction & building materials 2001-10, Vol.15 (7), p.329-337
1. Verfasser: Chew, M.Y.L
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The paper begins with a review of the currently available on-site water-tightness tests for masonry walls. The development of a modified on-site water chamber tester is reported. Results derived from experiments using this new tester are discussed. The results show that the leakage rate is not significantly affected by the flow rates but is significantly affected by the pressure difference of the applied water. Careful selection of a differential pressure seems to be more crucial than the water intensity rate for modelling realistic extreme wind driven rain situation in field-testing.