Deadbeat controller with two additional steps
An nth-order closed-loop hybrid system will exhibit a deadbeat response if the system output approaches the reference input in n steps. This paper studies the problem of obtaining a deadbeat response for an nth-order single-input single-output plant (process) in n + 2 steps with a minimum deadbeat c...
Gespeichert in:
Veröffentlicht in: | Elektronika ir elektrotechnika 2017-01, Vol.23 (5), p.11 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An nth-order closed-loop hybrid system will exhibit a deadbeat response if the system output approaches the reference input in n steps. This paper studies the problem of obtaining a deadbeat response for an nth-order single-input single-output plant (process) in n + 2 steps with a minimum deadbeat controller output deviation from the steady state value. We identify the requirements for the design of a deadbeat controller with two additional steps and present worked examples for the problem. A deadbeat controller is then used to control a piezoelectric micro-robot model. The second order continuous transfer function is used to simulate the robot's piezoelectric actuator. This research presents the advantages of a deadbeat controller with two additional steps when applied to a robot control problem. Index Terms--Control design; deadbeat control; digital control; robot control. |
---|---|
ISSN: | 1392-1215 2029-5731 |
DOI: | 10.5755/j01.eie.23.5.19115 |