Minimization of Specific Air Flows in Jet-Cooling Systems for Melting Tank Refractory Barriers in Glass Furnaces
The principles for validating rational parameters for air cooling systems for the critical zones of the melting tank in glass furnaces are formulated. An applied validation procedure making it possible to minimize the electricity consumption by blowers is developed.
Gespeichert in:
Veröffentlicht in: | Glass and ceramics 2016, Vol.72 (9-10), p.370-375 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The principles for validating rational parameters for air cooling systems for the critical zones of the melting tank in glass furnaces are formulated. An applied validation procedure making it possible to minimize the electricity consumption by blowers is developed. |
---|---|
ISSN: | 0361-7610 1573-8515 |
DOI: | 10.1007/s10717-016-9792-0 |