Analysis of the dynamics of electrocaloric response in ferroelectrics using a ferromagnetic resonator

A method is proposed for studying the dynamics of the electrocaloric response of a ferroelectric capacitor to the pulsed action of the electric field, and the results of measurements are reported. The temperature of the capacitor was measured with the help of a ferromagnetic film resonator. The sens...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Technical physics 2012, Vol.57 (1), p.55-58
Hauptverfasser: Semenov, A. A., Pakhomov, O. V., Beliavskiy, P. Yu, Es’kov, A. V., Karmanenko, S. F., Nikitin, A. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A method is proposed for studying the dynamics of the electrocaloric response of a ferroelectric capacitor to the pulsed action of the electric field, and the results of measurements are reported. The temperature of the capacitor was measured with the help of a ferromagnetic film resonator. The sensitivity of temperature measurements was ∼10 −4 K/kHz. The recalculated temperature dependence of the resonance frequency showed that the ferroelectric ceramic sample was heated by 0.065 K and was cooled by 0.041 K relative to the thermostat temperature under the action of high-voltage pulses. The relaxation time of the electrocaloric effect of the 0.87PMN-0.13PT relaxor ferroelectric ceramic is 4.5 μs.
ISSN:1063-7842
1090-6525
DOI:10.1134/S1063784212010227