Exploring the use of pulsed erbium lasers to retrieve a zirconia crown from a zirconia implant abutment

Background Removal of cement-retained implant fixed restorations when needed, can be challenging. Conventional methods of crown removal are time consuming and costly for patients and practitioners. This research explored the use of two different types of pulsed erbium lasers as a non-invasive tool t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:PloS one 2020-06, Vol.15 (6), p.e0233536-e0233536, Article 0233536
Hauptverfasser: Elkharashi, Ahmed, Grzech-Lesniak, Kinga, Deeb, Janina Golob, Abdulmajeed, Aous A., Bencharit, Sompop
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Removal of cement-retained implant fixed restorations when needed, can be challenging. Conventional methods of crown removal are time consuming and costly for patients and practitioners. This research explored the use of two different types of pulsed erbium lasers as a non-invasive tool to retrieve cemented zirconia crowns from zirconia implant abutments. Materials and methods Twenty identical zirconia crowns were cemented onto 20 identical zirconia prefabricated abutments using self-adhesive resin cement. The specimens were divided into two groups for laser assisted crown removal; G1 for erbium-doped yttrium aluminum garnet laser (Er: YAG), and G2 for erbium, chromium-doped yttrium, scandium, gallium and garnet (Er,Cr: YSGG). For the G1, after the first crown removal, the specimens were re-cemented and removed again using the Er:YAG laser. Times needed to remove the crowns were recorded and analyzed using ANOVA (alpha = 0.05). The surfaces of the crown and the abutment were further examined using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) analyses. Results The average times of zirconia crown removal from zirconia abutments were 5 min 20 sec and 5 min 15 sec for the Er:YAG laser of first and second experiments (G1), and 5 min 55 sec for the Er,Cr:YSGG laser experiment (G2). No statistical differences were observed among the groups. SEM and EDS examinations of the materials showed no visual surface damaging or material alteration from the two pulsed erbium lasers. Conclusions Both types of pulsed erbium lasers can be viable alternatives for retrieving a zirconia crown from a zirconia implant abutment. Despite operating at different wavelengths, the Er:YAG and Er,Cr:YSGG lasers, perform similarly in removing a zirconia crown from a zirconia implant abutment with similar parameters. There are no visual and elemental composition damages as a result of irradiation with pulsed erbium lasers.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0233536