Developing an electrochemical immunosensor for early diagnosis of hepatocellular carcinoma
Purpose This paper aims to report on the development of a novel electrochemical amperometric immunosensor to diagnose early hepatocellular carcinoma (HCC) by detecting the Midkine (MDK) biomarker. Design/methodology/approach Anti-Midkine antibodies were immobilized covalently through carbodiimides c...
Gespeichert in:
Veröffentlicht in: | Sensor review 2021-05, Vol.41 (2), p.125-134 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Purpose
This paper aims to report on the development of a novel electrochemical amperometric immunosensor to diagnose early hepatocellular carcinoma (HCC) by detecting the Midkine (MDK) biomarker.
Design/methodology/approach
Anti-Midkine antibodies were immobilized covalently through carbodiimides chemistry on carbon screen-printed electrodes modified with carboxylated multi-walled carbon nanotubes. The development process was characterized using cyclic voltammetry, electrochemical impedimetric spectroscopy, Fourier transform infrared spectroscopy and atomic force microscopy. Differential pulse voltammetry was used to investigate the immunosensor performance in detecting MDK antigen within the concentration range of 1 pg/ml to 100 ng/ml.
Findings
MDK immunosensor exhibited high sensitivity and linearity with a detection limit of 0.8 pg/ml and a correlation coefficient of 0.99. The biosensor also demonstrated high selectivity, stability and reproducibility.
Originality/value
The developed MDK immunosensor could be a promising tool to diagnose HCC and reduce the number of related deaths. |
---|---|
ISSN: | 0260-2288 1758-6828 |
DOI: | 10.1108/SR-02-2020-0030 |