Rotaglide Total Knee Arthroplasty: A Long-Term Follow-up Study

Background Mobile-bearing knee designs represent an alternative to conventional fixed-bearing implants in total knee arthroplasty. The purpose of this study was to determine the clinical results of a mobile-bearing knee implant. Methods From 1990 to 1998, 326 primary consecutive mobile-bearing total...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of bone and joint surgery. American volume 2011, Vol.93 (9), p.878-884
Hauptverfasser: Metsovitis, Stergios R., MD, Ploumis, Avraam L., MD, Chantzidis, Paraskevas T., MD, Terzidis, Ioannis P., MD, Christodoulou, Anastasios G., MD, Dimitriou, Christos G., MD, Tsakonas, Athanasios C., MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background Mobile-bearing knee designs represent an alternative to conventional fixed-bearing implants in total knee arthroplasty. The purpose of this study was to determine the clinical results of a mobile-bearing knee implant. Methods From 1990 to 1998, 326 primary consecutive mobile-bearing total knee prostheses were implanted in 260 patients who had a mean age and standard deviation of 66.7 ± 6.9 years. Femoral and tibial components were cemented in all knees, and the patella was resurfaced in 199 knees (61%). Patients were evaluated with the use of the Knee Society clinical rating system and radiographic examinations. Complications were noted, and survivorship of the prostheses was determined. Results The mean follow-up period was 156 ± 27.3 months, with maximum follow-up at eighteen years. The mean Knee Society knee score improved from 32.4 ± 21.2 preoperatively to 92.6 ± 10.0 at the time of the last follow-up (p = 0.00), and the mean Knee Society functional score improved from 39.3 ± 18.7 preoperatively to 66.7 ± 18.6 at the time of the last follow-up (p = 0.00). Mean knee flexion improved from 92.3° ± 14.5° preoperatively to 112.1° ± 13.4° at the time of the last follow-up (p = 0.00). There were twenty-four (7.4%) knees that required revision. In eighteen (5.5%) knees, worn out or broken polyethylene was found and a polyethylene-only exchange was done. Six knees (1.8%) were fully revised. The survival rate was 0.96 (95% confidence interval, 0.93 to 0.98) at ten years and 0.87 (95% confidence interval, 0.79 to 0.93) at eighteen years. Conclusions A fully congruent, mobile-bearing total knee prosthesis had excellent survivorship during the ten to eighteen-year follow-up interval. Level of Evidence Therapeutic Level IV . See Instructions to Authors for a complete description of levels of evidence.
ISSN:0021-9355
DOI:10.1016/S0021-9355(11)70831-1