Glenohumeral Contact Kinematics in Patients After Total Shoulder Arthroplasty
Background Knowledge of in vivo glenohumeral joint contact mechanics after total shoulder arthroplasty may provide insight for the improvement of patient function, implant longevity, and surgical technique. The objective of this study was to determine the in vivo glenohumeral joint contact locations...
Gespeichert in:
Veröffentlicht in: | Journal of bone and joint surgery. American volume 2010, Vol.92 (4), p.916-926 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background Knowledge of in vivo glenohumeral joint contact mechanics after total shoulder arthroplasty may provide insight for the improvement of patient function, implant longevity, and surgical technique. The objective of this study was to determine the in vivo glenohumeral joint contact locations in patients after total shoulder arthroplasty. We hypothesized that the glenohumeral joint articular contact would be centered on the glenoid surface because of the ball-in-socket geometric features of the implants. Methods Dual-plane fluoroscopic images and computer-aided design models were used to quantify patient-specific glenohumeral articular contact in thirteen shoulders following total shoulder arthroplasty. The reconstructed shoulder was imaged at arm positions of 0°, 45°, and 90° of abduction (in the coronal plane) and neutral rotation and at 90° of abduction with maximum internal and external rotation. The patients were individually investigated, and their glenohumeral joint contact centroids were reported with use of contact frequency. Results In all positions, the glenohumeral joint contact centroids were not found at the center of the glenoid surface but at an average distance (and standard deviation) of 11.0 ± 4.3 mm from the glenoid center. Forty (62%) of the sixty-five total contact occurrences were found on the superior-posterior quadrant of the glenoid surface. The position of 0° of abduction in neutral rotation exhibited the greatest variation of quadrant contact location; however, no contact was found on the superior-anterior quadrant of the glenoid surface in this position. Conclusions In vivo, glenohumeral joint contact after total shoulder arthroplasty is not centered on the glenoid surface, suggesting that kinematics after shoulder arthroplasty may not be governed by ball-in-socket mechanics as traditionally thought. Although contact locations as a function of arm position vary among patients, the superior-posterior quadrant seems to experience the most articular contact in the shoulder positions tested. Clinical Relevance The results from this study may serve as benchmark data for future studies aiming to determine optimum contact biomechanics of the glenohumeral joint following primary total shoulder arthroplasty. |
---|---|
ISSN: | 0021-9355 |
DOI: | 10.1016/S0021-9355(10)71276-5 |