Study of Type II and Type III Anodized Al 5052-0 in Aqueous DS2 Solutions

Corrosion behavior studies using short-time electrochemical techniques and long-term immersion tests of Types II and III anodized Al 5052-0 and uncoated Al 5052-0 were conducted in 30 vol% DS2 aqueous decontaminating solution. Test data indicated that Type III anodized Al 5052-0 provided significant...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Zabielski, Chester V, Levy, Milton
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Corrosion behavior studies using short-time electrochemical techniques and long-term immersion tests of Types II and III anodized Al 5052-0 and uncoated Al 5052-0 were conducted in 30 vol% DS2 aqueous decontaminating solution. Test data indicated that Type III anodized Al 5052-0 provided significantly greater resistance to degradation than Type II anodized Al 5052-0 or uncoated Al 5052-0.