Installation Restoration Program Phase 2. Confirmation/Quantification. Stage 1. Volume 1
A problem confirmation study was performed at seven sites on Selfridge ANGB identified in the Phase I investigation as requiring further study(Southwest Sanitary Landfill, Fire Training Area 2, Fire Training Area 1, West Ramp Fuel Spill Site, Tucker Creek Landfill, Northwest Landfill, and East Ramp...
Gespeichert in:
Hauptverfasser: | , , |
---|---|
Format: | Report |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A problem confirmation study was performed at seven sites on Selfridge ANGB identified in the Phase I investigation as requiring further study(Southwest Sanitary Landfill, Fire Training Area 2, Fire Training Area 1, West Ramp Fuel Spill Site, Tucker Creek Landfill, Northwest Landfill, and East Ramp Fuel Spill Site). The field investigation was conducted from November 1984 to July 1985 and included installation of 25 monitor wells, collection and analysis of groundwater samples from the monitor wells, and collection and analysis of soil samples from the West and East Ramp Sites. Analysis included VOA, TOC, Phenols, COD, Cadmium, Chromium, Copper, Lead, Nickel, Zinc, Petroleum Hydrocarbons, Oil and Grease, EP Toxicity, and Ignitibility. Based on the hydrogeologic complexity of the physical setting and the findings of the sampling and analytical work, follow-on investigations have been recommended at all seven sites. Keywords: Groundwater contamination; Confirmation study; Hazardous wastes; Hazardous substances; Groundwater monitoring; Selfridge ANGB; Hazardous materials. (mjm) |
---|