Worst-Case Stress Analysis of Receiver Power Supplies in Torpedo Mk 46 Mod 5 (NEARTIP)

A worst-case stress analysis of receiver power supplies in Torpedo Mk 46 Mod 5 (NEARTIP) was performed to identify any component application problems. Of the 97 components analyzed, none are overstressed (i.e., stress ratio greater than 1), and 10 exceed their recommended stress ratio based upon the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Gellner,R, Weisel,J
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Gellner,R
Weisel,J
description A worst-case stress analysis of receiver power supplies in Torpedo Mk 46 Mod 5 (NEARTIP) was performed to identify any component application problems. Of the 97 components analyzed, none are overstressed (i.e., stress ratio greater than 1), and 10 exceed their recommended stress ratio based upon the derating guidelines of NAVSEA 0967-LP-597-1010. Of the 10 components, six had voltage-related and four had power-related stress problems.
format Report
fullrecord <record><control><sourceid>dtic_1RU</sourceid><recordid>TN_cdi_dtic_stinet_ADA052241</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ADA052241</sourcerecordid><originalsourceid>FETCH-dtic_stinet_ADA0522413</originalsourceid><addsrcrecordid>eNrjZAgLzy8qLtF1TixOVQguKUotLlZwzEvMqSzOLFbIT1MISk1OzSxLLVIIyC8HksGlBQU5manFCpl5CiH5RQWpKfkKvtkKJmYKvvkpCqYKGn6ujkEhngGaPAysaYk5xam8UJqbQcbNNcTZQzelJDM5vrgkMy-1JN7RxdHA1MjIxNCYgDQAtDgzgA</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>report</recordtype></control><display><type>report</type><title>Worst-Case Stress Analysis of Receiver Power Supplies in Torpedo Mk 46 Mod 5 (NEARTIP)</title><source>DTIC Technical Reports</source><creator>Gellner,R ; Weisel,J</creator><creatorcontrib>Gellner,R ; Weisel,J ; ARINC RESEARCH CORP SAN DIEGO CA</creatorcontrib><description>A worst-case stress analysis of receiver power supplies in Torpedo Mk 46 Mod 5 (NEARTIP) was performed to identify any component application problems. Of the 97 components analyzed, none are overstressed (i.e., stress ratio greater than 1), and 10 exceed their recommended stress ratio based upon the derating guidelines of NAVSEA 0967-LP-597-1010. Of the 10 components, six had voltage-related and four had power-related stress problems.</description><language>eng</language><subject>Acoustic Detection and Detectors ; ACOUSTIC TORPEDOES ; CAPACITORS ; ELECTRIC POWER ; Electrical and Electronic Equipment ; ELECTRICAL PROPERTIES ; Electricity and Magnetism ; MALFUNCTIONS ; Neartip ; PARTS ; POWER SUPPLIES ; RESISTORS ; SEMICONDUCTOR DEVICES ; SONAR RECEIVERS ; STRESSES ; Torpedoes ; VOLTAGE ; Worst case analysis</subject><creationdate>1977</creationdate><rights>APPROVED FOR PUBLIC RELEASE</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,776,881,27544,27545</link.rule.ids><linktorsrc>$$Uhttps://apps.dtic.mil/sti/citations/ADA052241$$EView_record_in_DTIC$$FView_record_in_$$GDTIC$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Gellner,R</creatorcontrib><creatorcontrib>Weisel,J</creatorcontrib><creatorcontrib>ARINC RESEARCH CORP SAN DIEGO CA</creatorcontrib><title>Worst-Case Stress Analysis of Receiver Power Supplies in Torpedo Mk 46 Mod 5 (NEARTIP)</title><description>A worst-case stress analysis of receiver power supplies in Torpedo Mk 46 Mod 5 (NEARTIP) was performed to identify any component application problems. Of the 97 components analyzed, none are overstressed (i.e., stress ratio greater than 1), and 10 exceed their recommended stress ratio based upon the derating guidelines of NAVSEA 0967-LP-597-1010. Of the 10 components, six had voltage-related and four had power-related stress problems.</description><subject>Acoustic Detection and Detectors</subject><subject>ACOUSTIC TORPEDOES</subject><subject>CAPACITORS</subject><subject>ELECTRIC POWER</subject><subject>Electrical and Electronic Equipment</subject><subject>ELECTRICAL PROPERTIES</subject><subject>Electricity and Magnetism</subject><subject>MALFUNCTIONS</subject><subject>Neartip</subject><subject>PARTS</subject><subject>POWER SUPPLIES</subject><subject>RESISTORS</subject><subject>SEMICONDUCTOR DEVICES</subject><subject>SONAR RECEIVERS</subject><subject>STRESSES</subject><subject>Torpedoes</subject><subject>VOLTAGE</subject><subject>Worst case analysis</subject><fulltext>true</fulltext><rsrctype>report</rsrctype><creationdate>1977</creationdate><recordtype>report</recordtype><sourceid>1RU</sourceid><recordid>eNrjZAgLzy8qLtF1TixOVQguKUotLlZwzEvMqSzOLFbIT1MISk1OzSxLLVIIyC8HksGlBQU5manFCpl5CiH5RQWpKfkKvtkKJmYKvvkpCqYKGn6ujkEhngGaPAysaYk5xam8UJqbQcbNNcTZQzelJDM5vrgkMy-1JN7RxdHA1MjIxNCYgDQAtDgzgA</recordid><startdate>197708</startdate><enddate>197708</enddate><creator>Gellner,R</creator><creator>Weisel,J</creator><scope>1RU</scope><scope>BHM</scope></search><sort><creationdate>197708</creationdate><title>Worst-Case Stress Analysis of Receiver Power Supplies in Torpedo Mk 46 Mod 5 (NEARTIP)</title><author>Gellner,R ; Weisel,J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-dtic_stinet_ADA0522413</frbrgroupid><rsrctype>reports</rsrctype><prefilter>reports</prefilter><language>eng</language><creationdate>1977</creationdate><topic>Acoustic Detection and Detectors</topic><topic>ACOUSTIC TORPEDOES</topic><topic>CAPACITORS</topic><topic>ELECTRIC POWER</topic><topic>Electrical and Electronic Equipment</topic><topic>ELECTRICAL PROPERTIES</topic><topic>Electricity and Magnetism</topic><topic>MALFUNCTIONS</topic><topic>Neartip</topic><topic>PARTS</topic><topic>POWER SUPPLIES</topic><topic>RESISTORS</topic><topic>SEMICONDUCTOR DEVICES</topic><topic>SONAR RECEIVERS</topic><topic>STRESSES</topic><topic>Torpedoes</topic><topic>VOLTAGE</topic><topic>Worst case analysis</topic><toplevel>online_resources</toplevel><creatorcontrib>Gellner,R</creatorcontrib><creatorcontrib>Weisel,J</creatorcontrib><creatorcontrib>ARINC RESEARCH CORP SAN DIEGO CA</creatorcontrib><collection>DTIC Technical Reports</collection><collection>DTIC STINET</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Gellner,R</au><au>Weisel,J</au><aucorp>ARINC RESEARCH CORP SAN DIEGO CA</aucorp><format>book</format><genre>unknown</genre><ristype>RPRT</ristype><btitle>Worst-Case Stress Analysis of Receiver Power Supplies in Torpedo Mk 46 Mod 5 (NEARTIP)</btitle><date>1977-08</date><risdate>1977</risdate><abstract>A worst-case stress analysis of receiver power supplies in Torpedo Mk 46 Mod 5 (NEARTIP) was performed to identify any component application problems. Of the 97 components analyzed, none are overstressed (i.e., stress ratio greater than 1), and 10 exceed their recommended stress ratio based upon the derating guidelines of NAVSEA 0967-LP-597-1010. Of the 10 components, six had voltage-related and four had power-related stress problems.</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_dtic_stinet_ADA052241
source DTIC Technical Reports
subjects Acoustic Detection and Detectors
ACOUSTIC TORPEDOES
CAPACITORS
ELECTRIC POWER
Electrical and Electronic Equipment
ELECTRICAL PROPERTIES
Electricity and Magnetism
MALFUNCTIONS
Neartip
PARTS
POWER SUPPLIES
RESISTORS
SEMICONDUCTOR DEVICES
SONAR RECEIVERS
STRESSES
Torpedoes
VOLTAGE
Worst case analysis
title Worst-Case Stress Analysis of Receiver Power Supplies in Torpedo Mk 46 Mod 5 (NEARTIP)
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-29T13%3A41%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-dtic_1RU&rft_val_fmt=info:ofi/fmt:kev:mtx:book&rft.genre=unknown&rft.btitle=Worst-Case%20Stress%20Analysis%20of%20Receiver%20Power%20Supplies%20in%20Torpedo%20Mk%2046%20Mod%205%20(NEARTIP)&rft.au=Gellner,R&rft.aucorp=ARINC%20RESEARCH%20CORP%20SAN%20DIEGO%20CA&rft.date=1977-08&rft_id=info:doi/&rft_dat=%3Cdtic_1RU%3EADA052241%3C/dtic_1RU%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true