Worst-Case Stress Analysis of Receiver Power Supplies in Torpedo Mk 46 Mod 5 (NEARTIP)

A worst-case stress analysis of receiver power supplies in Torpedo Mk 46 Mod 5 (NEARTIP) was performed to identify any component application problems. Of the 97 components analyzed, none are overstressed (i.e., stress ratio greater than 1), and 10 exceed their recommended stress ratio based upon the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Gellner,R, Weisel,J
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A worst-case stress analysis of receiver power supplies in Torpedo Mk 46 Mod 5 (NEARTIP) was performed to identify any component application problems. Of the 97 components analyzed, none are overstressed (i.e., stress ratio greater than 1), and 10 exceed their recommended stress ratio based upon the derating guidelines of NAVSEA 0967-LP-597-1010. Of the 10 components, six had voltage-related and four had power-related stress problems.