DEVELOPMENT OF MAGNESIUM FLAT CELL BATTERY
A review of development work during the 24 month contract plus a more detailed discussion of the past 8 months work is presented. Initial and delayed BA-4399 capacity results, capacity maintenance and percent moisture loss figures on flat cell batteries are included. Particular emphasis was placed o...
Gespeichert in:
1. Verfasser: | |
---|---|
Format: | Report |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A review of development work during the 24 month contract plus a more detailed discussion of the past 8 months work is presented. Initial and delayed BA-4399 capacity results, capacity maintenance and percent moisture loss figures on flat cell batteries are included. Particular emphasis was placed on capacity and capacity maintenance of batteries after storage at 130F and 160F for 1 to 3 months. Methods of improving capacity maintenance and reducing moisture loss after these storage conditions are described. Design investigations on several larger size flat cells for use in the BA-4386 battery are given, including initial and delayed capacity figures. Battery design was completed using NS size flat cells in the BA-4386 battery, and initial capacity results are reported. (Author) |
---|