The Viscosity of Deuterohydrogen at Constant Density in the Temperature Range 20.4-300K
The study concerns determination of the viscosity of hydrogen isotopes at constant density. The viscosity of deuterohydrogen was measured by a previously described method. The measurement error in the given work did not exceed 5 percent. Studies were conducted at temperatures from 20.4 to 300K with...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Report |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The study concerns determination of the viscosity of hydrogen isotopes at constant density. The viscosity of deuterohydrogen was measured by a previously described method. The measurement error in the given work did not exceed 5 percent. Studies were conducted at temperatures from 20.4 to 300K with densities of 0.1173-0.00375 g/cu cm. (Author)
Edited machine trans. of Ukrayinskyi Fizychnyi Zhurnal (USSR) v14 n11 p1913-1915 1969, by H. Miller. |
---|