The Murayama Test for Hemoglobin S: A Simplification in Technique
An improvement is reported in the technique of the Murayama test, a simple specific test for hemoglobin S reported originally by this laboratory in 1970. The improvements consist of: (1) the optional use of N2 or dry ice; and (2) the elimination of several steps in the test for the preparation of co...
Gespeichert in:
Hauptverfasser: | , , , , |
---|---|
Format: | Report |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An improvement is reported in the technique of the Murayama test, a simple specific test for hemoglobin S reported originally by this laboratory in 1970. The improvements consist of: (1) the optional use of N2 or dry ice; and (2) the elimination of several steps in the test for the preparation of concentrated hemolysates by use of a dense sucrose-detergent lysing solution. This reduces the performance time per test from 1 hour to 20 minutes, without adverse effect on reliability or accuracy of the test result. (Author) |
---|