CALIBRATION OF THE NOL LARGE SCALE GAP TEST WITH A PENTOLITE DONOR II

Henceforth the standard donor in the NOL large scale gap test will be 50/50 pentolite pellets pressed to a density of 1.56 g/cc instead of the tetryl pellets previously used. The pentolite donors will be supplied by NAD, Crane, Indiana. This report gives the current calibration curve for the large s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: Price, Donna
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Henceforth the standard donor in the NOL large scale gap test will be 50/50 pentolite pellets pressed to a density of 1.56 g/cc instead of the tetryl pellets previously used. The pentolite donors will be supplied by NAD, Crane, Indiana. This report gives the current calibration curve for the large scale gap test with the pentolite donors.