MILITARY BLOOD BANKING - IDENTIFICATION OF THE GROUP O UNIVERSAL DONOR FOR TRANSFUSION OF A, B AND AB RECIPIENTS - AN ENIGMA OF TWO DECADES
In a recent survey of Army personnel, titers in excess of 1:256, when tested against fresh A sub 1 erythrocytes, were encountered in a large number of group O individuals. In vitro testing revealed the presence of anti-A and anti-B antibodies which were found to have been stimulated by contamination...
Gespeichert in:
Hauptverfasser: | , |
---|---|
Format: | Report |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext bestellen |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In a recent survey of Army personnel, titers in excess of 1:256, when tested against fresh A sub 1 erythrocytes, were encountered in a large number of group O individuals. In vitro testing revealed the presence of anti-A and anti-B antibodies which were found to have been stimulated by contamination of immunization products. These findings illustrate an additional complexity of the long-standing problem of defining reliable parameters for the identification of the safe group O blood (Universal Donor) for transfusion to A, B AND AB recipients. (Author) |
---|