MAGNETICALLY CONTROLLED GAS DUPLEXER

An investigation is described leading to the development of a high power microwave gas duplexer utilizing a fixed external magnetic field to improve switching efficiency within the limit of a specified recovery time. The magnetic field is transverse, i.e., perpendicular to both the microwave electri...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
1. Verfasser: WARD,Charles S
Format: Report
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An investigation is described leading to the development of a high power microwave gas duplexer utilizing a fixed external magnetic field to improve switching efficiency within the limit of a specified recovery time. The magnetic field is transverse, i.e., perpendicular to both the microwave electric field and the narrow waveguide sidewalls, and parallel to the axis of the discharge tube. It is shown that under appropriate conditions such a field simultaneously produces substantial reductions in both recovery time and discharge arc loss. A prototype duplexer utilizing this effect and designed to operate at 50 megawatts peak100 kilowatts average in S-band is described. (Author) See also AD-604 755.