Electro-Stimulation System with Artificial-Intelligence-Based Auricular-Triggered Algorithm to Support Facial Movements in Peripheral Facial Palsy: A Simulation Pilot Study

Facial palsy causes severe functional disorders and impairs quality of life. Disturbing challenges for patients with acute facial palsy, but also with those with chronic facial palsy with synkinesis, are the loss of the ability to smile and insufficient eyelid closure. A potential treatment for thes...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diagnostics (Basel) 2024-09, Vol.14 (19), p.2158
Hauptverfasser: Steiner, Katharina, Arnz, Marius, Volk, Gerd Fabian, Guntinas-Lichius, Orlando
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Facial palsy causes severe functional disorders and impairs quality of life. Disturbing challenges for patients with acute facial palsy, but also with those with chronic facial palsy with synkinesis, are the loss of the ability to smile and insufficient eyelid closure. A potential treatment for these conditions could be a closed-loop electro-stimulation system that stimulates the facial muscles on the paretic side as needed to elicit eye closure, eye blink and smile in a manner similar to the healthy side. This study focuses on the development and evaluation of such a system. An artificial intelligence (AI)-based auricular-triggered algorithm is used to classify the intended facial movements. This classification is based on surface electromyography (EMG) recordings of the extrinsic auricular muscles, specifically the anterior, superior, and posterior auricular muscle on the paretic side. The system then delivers targeted surface electrical stimulation to contract the appropriate facial muscles. The evaluation of the system was conducted with 17 patients with facial synkinesis, who performed various facial movements according to a paradigm video. The system's performance was evaluated through a simulation, using previously captured data as the inputs. The performance was evaluated by means of the median macro F1-score, which was calculated based on the stimulation signal (output of the system) and the actual movements the patients performed. This study showed that such a system, using an AI-based auricular-triggered algorithm, can support with a median macro F1-score of 0.602 for the facial movements on the synkinetic side in patients with unilateral chronic facial palsy with synkinesis.
ISSN:2075-4418
2075-4418
DOI:10.3390/diagnostics14192158